Cat

Name

Size

Price

Action

VP 418MW2H-1X8H-50
MagWash® System for Eight, 25mL or 50mL Conical Bottom SpinVessel® (in a 1x8 array), to Produce a 50mm by 10.5mm Pellet Along One Side of the SpinVessel® that is 9.8mm Above the Bottom of the SpinVessel® for Safe Pipetting, Designed for High-Volume Separation (up to 50mL), The Array is Made to Fit on Hamilton Star and Vantage Liquid Handlers, Computer Controlled via ASCII Commands, 100/240 Volts, 50/60 Hz, CE Compliant, US Patent Pending, European Patent #3887049
1 EACH

Ask

VP 418MW2-1X8HV50-CC
MagWash® System for Eight, 25mL or 50mL Conical Bottom SpinVessel® (in a 1x8 array) , to Produce a 50mm by 10.5mm Pellet Along One Side of the SpinVessel® that is 9.8mm Above the Bottom of the SpinVessel® for Safe Pipetting, Designed for High-Volume Separation (up to 50mL) , The Array is Made to Fit on Tecan Evo and Fluent Liquid Handlers, Computer Controlled via ASCII Commands, 100/240 Volts, 50/60 Hz, CE Compliant, US Patent Pending, European Patent #3887049, Sweden Patent #19889987.4
1 Each

Ask

VP 418MWA-1X8-50-HV
MagWash® Attachment for 1x8 SpinVessel®, Holds Eight, 52MGO Magnets to Produce a High-Volume Array With Eight Pellets 50mm by 10.5mm Along One Side of Each SpinVessel® and 9.8mm Above the Bottom of the SpinVessel®, Designed for High-Volume Separation (up to 50mL)
1 EACH

Ask

VP 771TN-G-5A
MAGNETIC BEAD SEPARATION PLATE, 384 Well, Standard Plate, Flat Bottom, 425 Round Posts, 52MGO, NdFeB Magnets, Red Anodized Aluminum Magnet Frame, 2 Sided Pellet Location, 3.1mm Post Diameter, Axial - North Poles Up Magnetic Orientation, Gripper Accessible, Designed To Fit Plate Tray of Tecan Hydrospeed Plate Washer, Magnets In 25 X 17 Array That Is Positioned Such That Each Well Has a Magnet On Opposing Sides of the Well, Top and Bottom, Non-SLAS Footprint, No Registration Base
1 EACH

Ask

VP 772F11A-HV
MAGNETIC BEAD SEPARATION RACK, Two-Part Design with Magnetic Base and Top Rack (4x6 Array), 24 Flip Top Microcentrifuge Tubes, 1.5mL or 2.0mL Volume, Two Pellet Locations – Top and Bottom on 1 Side, 52MGO, NdFeB Magnet, 19mm Center Spacing in X, 18mm Center Spacing in Y, 11.1mm Hole Diameter, PLA
1 EACH

Ask

VP 418MW2-1X8HV50
MagWash® System for Eight, 25mL or 50mL Conical Bottom SpinVessel® (in a 1x8 Array) , to Produce a 50mm by 10.5mm Diameter Pellet Along One Side of the SpinVessel® that is 9.8mm Above the Bottom of the SpinVessel® for Safe Pipetting, Designed for High-Volume Separation (up to 50mL) , the Array is Made to Fit on Tecan Evo and Fluent Liquid Handlers, Manual Touch Screen Controller, 100/240 Volts, 50/60 Hz, CE Compliant, US Patent Pending, European Patent #3887049, Sweden Patent #19889987.4
1 Each

Ask

VP 772F11A
MAGNETIC BEAD SEPARATION RACK, Two-Part Design with Magnetic Base and Top Rack (4x6 Array) 24 Flip Top Microcentrifuge Tubes, 1.5mL or 2.0mL Volume, 1 Sided Bead Pellet Location, Low Position, 52MGO, NdFeB Magnet, 18mm Center Spacing in X, 19mm Center Spacing in Y, 11.1mm Hole Diameter, PLA
1 EACH

Ask

VP 418MW2-2-50HL-CC
MagWash® System for Two, 25mL or 50mL SpinVessels® (in a 1x2 array), the First Position has a Large Magnet to Produce a 50mm by 10.5mm Pellet Along One Side of the SpinVessel® that is 9.8mm Above the Bottom of the SpinVessel® for Safe Pipetting, Designed for High-Volume Separation (up to 50mL), the Second Position has Four NdFeB Magnets Under the Drive Base to Produce Four Pellets10mm in Diameter, 3.5mm Above the Bottom of the SpinVessel® for Safe Pipetting, Designed for Low-Volume Separation (less than 25mL), the Motor Box has SLAS Dimensions, Direct Drive Stepper Motor, Aluminum Enclosure, and is Computer Controlled via ASCII Commands, 100/240 Volts, 50/60 Hz, CE Compliant, US Patent Pending, European Patent #3887049, Sweden Patent #19889987.4
1 EACH

Ask

VP 418MW2-2-50-L
MagWash® System for Two, 25mL or 50mL SpinVessels® (in a 1×2 array) , the First Position has Four Magnets per Tube, Designed for Low-Volume Separation less than 25mL, SLAS Dimensions, Direct Drive Stepper Motor, Aluminum Enclosure, Manual Touch Screen Controller, 100-240 Volts, 50-60 Hz, CE Compliant, US Patent Pending, European Patent #3887049, Sweden Patent #19889987.4
1 Each

Ask

VP 418SV2-2-50-MW
SpinVessel® ACCESSORY, MagWash® Adapter, Converts SpinVessel® into MagWash®, Holds Magnets in Low-Volume Array Around 25mL/50mL SpinVessel® for Single or Multi-Position MagWash®, Produces Four Pellets 10mm in Diameter, 3.5mm Above the Bottom of the SpinVessel® for Safe Pipetting Designed for Low-Volume Separation (less than 25mL)
1 EACH

Ask

VP 418MW2H-1X8TE-50
MagWash® System for Eight, 25mL or 50mL Conical Bottom SpinVessel® (in a 1x8 array), to Produce a 50mm by 10.5mm Pellet Along One Side of the SpinVessel® that is 9.8mm Above the Bottom of the SpinVessel® for Safe Pipetting, Designed for High-Volume Separation (up to 50mL), Fits on Tecan Evo Liquid Handler, Tecan Fluent Requires Adapter, Computer Controlled via ASCII Commands, 100/240 Volts 50/60 Hz, CE Compliant, US Patent Pending, European Patent #3887049
1 EACH

Ask

VP 418MW2-2-50-L-CC
MagWash® System for Two, 25mL or 50mL SpinVessels® (in a 1x2 array), Four NdFeB Magnets Under the Drive Base, to Produce Four Pellets 10mm in Diameter that are 3.5mm Above the Bottom of the SpinVessel® for Safe Pipetting, Designed for Low-Volume Separation (less than 25mL), the Second Position Does Not Have Any Magnets, the Motor Box has SLAS Dimensions, Direct Drive Stepper Motor, Aluminum Enclosure, Computer Controlled via ASCII Commands, 100/240 Volts, 50/60 Hz, CE Compliant, US Patent Pending, European Patent #3887049, Sweden Patent #19889987.4
1 EACH

Ask

VP 771V-1
MAGNETIC BEAD SEPARATION PLATE, 96 Well, PCR Plate, V-Bottom, 12 Bar Halbach Array, 52MGO, NdFeB Magnets, Gold Anodized Aluminum Magnet Frame, 1 Sided Pellet Location, Halbach Array, Gripper Accessible, for Half-Skirt, Not for Full-Skirt, Beads Collected to a Single Side of a Row of Wells, SLAS Footprint, No Registration Base
1 EACH

Ask

VP 771V-2
MAGNETIC BEAD SEPARATION PLATE, 96 Well, PCR Plate, V-Bottom, 12 Bar Halbach Array, 52MGO, NdFeB, Magnets, Gold Anodized Aluminum Magnet Frame, 1 Sided Pellet Location, Halbach Array, Beads collected to a single side of a row of wells, 1.5mm Thick Bottom Plate, designed to allow Microplate to sit flat on Cytena C.Wash platform, Non-SLAS Footprint, No Registration Base
1 EACH

Ask